Question from customer:

I need a four channel receiver and transmitter to control lights or LEDs at 300 meters, 12 volt DC power. Do you have a system? Please respond as soon as possible. Large quantities are possible if we can find the right controlling system.

Answer:

4 channel 12VDC Power Output Switch Kit (S4X-DC12-ANT2&CB-4L) is your better choice. 4 lights or LED lamps can be wired to its channels. And 4 lamps can get power directly from the powered receiver. It is very convenient to you because you don’t have to supply additional power to lights. 2000m can be reached in the open field with the external extend magnetic antenna. Besides controlling lights, it can be applied to many fields, such as motors, fans, electrically operated doors / locks / windows / blinds / cars or other appliances.

1

Here is the wiring diagram. It is simple to wire lights. Wire four lights to A&B terminals from relay 1 to relay 4. Supply 12VDC to the receiver.

1_06

There are four working modes in this kit. They are toggle, momentary, latched, momentary + toggle modes.

Setting different control modes

•1) Setting control mode Toggle: Only connect Jumper-2.

Press button A: Turn on the relay 1, terminal OUT 1 (A&B) outputs DC power.

Press button A again: Turn off the relay 1, terminal OUT 1 no output.

Press button B: Turn on the relay 2, terminal OUT 2 (A&B) outputs DC power.

Press button B again: Turn off the relay 2, terminal OUT 2 no output.

……

•2) Setting control mode Momentary: Only connect Jumper-1.

Press and hold button A: Turn on the relay 1, terminal OUT 1 (A&B) outputs DC power.

Release button A: Turn off the relay 1, terminal OUT 1 no output.

Press and hold button B: Turn on the relay 2, terminal OUT 2 (A&B) outputs DC power.

Release button B: Turn off the relay 2, terminal OUT 2 no output.

……

•3) Setting control mode Latched: Do not connect Jumper-1 and Jumper-2.

Press button A: Turn on the relay 1, terminal OUT 1 (A&B) outputs DC power.

Turn off the relay 2, terminal OUT 2 no output.

Press button B: Turn on the relay 2, terminal OUT 2 (A&B) outputs DC power.

Turn off the relay 1, terminal OUT 1 no output.

……

•4) Setting control mode Momentary (Channel 1~2) + Toggle (Channel 3~4): Connect Jumper-1 and Jumper-2.